Abstract :
This paper presents undergoing research results of a near infrared CCD imaging system designed for mapped acquisition of hemodynamics data with inexpensive system components. This system is intended for use by clinicians and in phenological practice. The tests that can currently be done with this system are the classical Muscle Pump Test (MPT) and the Vein Occlusion Test (VOT). These are standard tests for venous disorders such as chronic vein insufficiency (CVI) and deep vein thrombosis (DVT). Photoplethysmographic (PPG) systems with NIR optical sensors are in wide use for these tests today. They essentially measure the blood volume changes in the top skin layers by registering the attenuation change in the near infrared. The new principle is based on this method but allows imaging of the vein structure as well as mapping the physiological data to the image. A monochrome CCD camera equipped with a >700 nm filter is mounted on a tripod. A diffuse illumination is applied, then the test is performed. The camera takes a sequence of pictures of the perfusion area of interest, usually the lower leg. The sequence is then evaluated and filtered with digital filter algorithms. This allows calculation of parameters such as venous refilling time, venous pump power and venous drainage. These values are offered to the examiner as mapped data from several selectable regions. From this, conclusions can be taken as to the reason and location of disorders
Keywords :
CCD image sensors; biomedical equipment; biomedical imaging; data acquisition; haemodynamics; infrared imaging; plethysmography; volume measurement; 700 nm; attenuation change; blood volume changes; chronic vein insufficiency; deep vein thrombosis; diffuse illumination; lower leg; mapped hemodynamic data acquisition; medical diagnostic imaging; medical instrumentation; monochrome CCD camera; near infrared CCD imaging; photoplethysmographic systems; pictures sequence; top skin layers; venous disorders; Charge coupled devices; Data acquisition; Digital filters; Hemodynamics; Infrared imaging; Muscles; Optical imaging; Optical sensors; System testing; Veins;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-4262-3
Type :
conf
DOI :
10.1109/IEMBS.1997.757694
Filename :
757694
Link To Document :
بازگشت