DocumentCode
2708690
Title
FD-TD analysis for coaxial probe inserted into a waveguide
Author
Sanada, Atsushi ; Sanagi, Minoru ; Nogi, Shigeji ; Yamane, Kuniyoshi
Author_Institution
Dept. of Commun. Eng., Okayama Univ., Japan
Volume
3
fYear
1997
fDate
2-5 Dec 1997
Firstpage
957
Abstract
Full wave FD-TD analysis has been carried out for a coaxial probe inserted into a waveguide so as to achieve a coaxial-waveguide transition. Including cases for probes with large diameter and extension length, equivalent admittances agreed well with corresponding measured results and have been provided as useful data for circuit design. Field concentration which ought to be taken into account for high power application design has been also discussed by field distribution
Keywords
electric admittance; finite difference time-domain analysis; probes; rectangular waveguides; waveguide theory; coaxial probe; coaxial-waveguide transition; equivalent admittances; field concentration; field distribution; full wave FDTD analysis; high power application design; waveguide insertion; Admittance; Circuit synthesis; Coaxial cables; Coaxial components; Conductors; Finite difference methods; Length measurement; Power dividers; Probes; Waveguide transitions;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference Proceedings, 1997. APMC '97, 1997 Asia-Pacific
Print_ISBN
962-442-117-X
Type
conf
DOI
10.1109/APMC.1997.656360
Filename
656360
Link To Document