• DocumentCode
    2709296
  • Title

    Parallel Operation Control of N+1 Redundant Inverter System

  • Author

    Byung-Hwan Jeong ; Jong-Chan Park ; Gyu-Ha Choe ; Jun-Seok Cho

  • Author_Institution
    Dept. of Electr. Eng., Kon-Kuk Univ., Seoul
  • fYear
    2006
  • fDate
    18-22 June 2006
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    In this paper, a novel parallel operation algorithm of N+1 redundant inverter system with no control interconnections for load-sharing is presented. The proposed control system eliminates the sensing noise and interconnection interface of conventional parallel operation system. To reduce a reactive power deviation in wireless control method, this technique automatically compensates for inverter parameter variation and line impedance imbalances with wireless auto-tuning method. In addition, to increase reliability on transient characteristics of parallel operation, a virtual injected impedance is adopted to eliminate a circulation current among inverter modules. Simulation results are provided in this paper to prove the proposed novel algorithm
  • Keywords
    distributed control; invertors; telecontrol; N+1 redundant inverter system; inverter parameter variation; line impedance imbalances; parallel operation control; reactive power deviation; sensing noise elimination; virtual injected impedance; wireless auto-tuning method; wireless control method; Automatic control; Batteries; Control systems; Impedance; Inverters; Power system interconnection; Power system reliability; Reactive power; Reactive power control; Uninterruptible power systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2006. PESC '06. 37th IEEE
  • Conference_Location
    Jeju
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-9716-9
  • Type

    conf

  • DOI
    10.1109/PESC.2006.1711739
  • Filename
    1711739