DocumentCode :
2709614
Title :
The analysis and simulation to the add-in DC reverse testing pulse based current-leakage protection method for DC trolley system
Author :
Hong, Cheng ; Cong, Wang ; Qi-wei, Lu ; Dong-hua, Wang
Author_Institution :
Dept. of Inf. & Electr. Eng., China Univ. of Min. & Technol., Beijing
fYear :
2008
fDate :
21-24 April 2008
Firstpage :
1
Lastpage :
5
Abstract :
Based on the analysis to various current-leakage protection methods for DC trolley system, especially to the method based on add-in AC testing signal, a research on a new current-leakage protection method for DC trolley system based on add-in DC-reverse testing pulse is presented. Considering of the effects of four distributing parameters of the long wire, i.e. line inductance L, line capacitance C, line conductance G and line resistance R, the design principle of the controller for current-leakage protection system of DC trolley system is discussed in detail, and the corresponding simulation results are presented in this paper which validate the correctness of the analysis to the above mentioned new method.
Keywords :
leakage currents; overcurrent protection; trolleys; DC trolley system; add-in AC testing signal; add-in DC reverse testing pulse; current-leakage protection methods; distributing parameters; Accidents; Analytical models; Circuit faults; Fault currents; Fault detection; Information analysis; Signal analysis; Substation protection; System testing; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Technology, 2008. ICIT 2008. IEEE International Conference on
Conference_Location :
Chengdu
Print_ISBN :
978-1-4244-1705-6
Electronic_ISBN :
978-1-4244-1706-3
Type :
conf
DOI :
10.1109/ICIT.2008.4608660
Filename :
4608660
Link To Document :
بازگشت