Abstract
The applicability of open- and balance-type calorimeter in energy efficiency level classifications of frequency converters is studied and compared with an input-output method carried out by a power analyser. The effect of heat source location and the frequency converter ventilation fan is tested and analysed.
Keywords
calorimeters; fans; frequency convertors; ventilation; VSC loss measurement; balance-type calorimeter; energy efficiency level classifications; frequency converter ventilation fan; frequency converters; heat source location; input-output method; open-type calorimeter; power analyser; Electron tubes; Frequency conversion; Heating; Loss measurement; Resistors; Temperature measurement; Temperature sensors; Efficiency; electrical drive; industrial application; measurement; voltage source converter;