• DocumentCode
    271441
  • Title

    Applicability of an open- and balance-type calorimeter to VSC loss measurement

  • Author

    Aarniovuori, L. ; Kosonen, A. ; Niemelä, Markku ; Pyrhönen, Juha

  • Author_Institution
    Lappeenranta Univ. of Technol., Lappeenranta, Finland
  • fYear
    2014
  • fDate
    26-28 Aug. 2014
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    The applicability of open- and balance-type calorimeter in energy efficiency level classifications of frequency converters is studied and compared with an input-output method carried out by a power analyser. The effect of heat source location and the frequency converter ventilation fan is tested and analysed.
  • Keywords
    calorimeters; fans; frequency convertors; ventilation; VSC loss measurement; balance-type calorimeter; energy efficiency level classifications; frequency converter ventilation fan; frequency converters; heat source location; input-output method; open-type calorimeter; power analyser; Electron tubes; Frequency conversion; Heating; Loss measurement; Resistors; Temperature measurement; Temperature sensors; Efficiency; electrical drive; industrial application; measurement; voltage source converter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE'14-ECCE Europe), 2014 16th European Conference on
  • Conference_Location
    Lappeenranta
  • Type

    conf

  • DOI
    10.1109/EPE.2014.6910932
  • Filename
    6910932