Title :
On-line monitoring of stator winding insulation-the manufacturer and service engineer´s view
Author_Institution :
GEC Alsthom Large Machines Ltd., Rugby, UK
Abstract :
GEC Alsthom helped to pioneer the installation of monitoring systems based on capacitive couplers in the UK and has now been engaged in this field of work for over ten years. Many industries and utilities regard on-line monitoring of stator winding insulation as important. This is especially true of those operating hydroelectric generators and critical rotating machines on oil platforms. Electrical machine operators in other continuous process industries are also now using this form of monitoring. The author briefly discusses on-line monitoring techniques, including partial discharge measurement, and their benefits to users
Keywords :
charge measurement; computerised monitoring; electric machines; insulation testing; machine insulation; machine testing; partial discharges; stators; GEC Alsthom; capacitive couplers; continuous process industries; hydroelectric generators; oil platforms; on-line monitoring; partial discharge measurement; rotating machines; stator winding insulation;
Conference_Titel :
Condition Monitoring of Electrical Machines, IEE Colloquium on
Conference_Location :
London
DOI :
10.1049/ic:19950099