• DocumentCode
    2722647
  • Title

    Operating experience of Tore Supra superconducting magnets

  • Author

    Turck, B. ; Torossian, A.

  • Author_Institution
    Dept. de Recherche sur la Fusion Controlee, CEA, Centre d´´Etudes Nucleaires de Cadarache, France
  • Volume
    1
  • fYear
    1993
  • fDate
    11-15 Oct 1993
  • Firstpage
    393
  • Abstract
    After a description of the peculiar features of the Tore Supra magnet is given, the paper reports about the 4 year operating experience, with particular emphasis on the protection systems, the mechanical behaviour of the coil under repetitive loadings, the operation of the 1.8 K cooling system and the thermal loads. The Tore Supra superconducting magnet has been routinely operated with a current maintained constant on a whole day basis, for a programme of more than 10000 shots. Only one quench has been detected for which the protection system reacted as expected
  • Keywords
    Tokamak devices; cooling; fusion reactor design; fusion reactors; overvoltage protection; protection; refrigeration; superconducting magnets; 1.8 K; 4 y; Tore Supra; cooling system; mechanical behaviour; operating experience; protection systems; quench; superconducting magnets; thermal loads; Conductors; Dielectrics and electrical insulation; Helium; Magnetic separation; Plasma properties; Protection; Superconducting coils; Superconducting magnets; Tokamaks; Toroidal magnetic fields;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1993., 15th IEEE/NPSS Symposium on
  • Conference_Location
    Hyannis, MA
  • Print_ISBN
    0-7803-1412-3
  • Type

    conf

  • DOI
    10.1109/FUSION.1993.518357
  • Filename
    518357