DocumentCode :
272646
Title :
Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images
Author :
Haak, Alexander ; Vegas-Sanchez-Ferrero, Gonzalo ; Mulder, Harriet W. ; Ben Ren ; Kirişli, Hortense A. ; Metz, Coert ; van Burken, Gerard ; van Stralen, Marijn ; Pluim, Josien P. W. ; van der Steen, F.W. ; van Walsum, Theo ; Bosch, Johannes G.
Author_Institution :
Dept. of Biomed. Eng. of the Thoraxcenter, Erasmus MC, Rotterdam, Netherlands
Volume :
62
Issue :
6
fYear :
2015
fDate :
Jun-15
Firstpage :
1179
Lastpage :
1189
Abstract :
Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations.
Keywords :
blood; computerised tomography; diagnostic radiography; echocardiography; image classification; image segmentation; medical image processing; mixture models; principal component analysis; probability; ultrasonic imaging; 3D TEE image data; 3D TEE segmentation; 3D transesophageal ultrasound imaging; ASM segmentations; CTA derived segmentations; CTA segmentations; GMM; Philips X7-2t matrix TEE probe; aorta; atrium; automated segmentation; catheter guidance; computed tomography angiography segmentations; gamma mixture model; heart cavities; intervention monitoring; manually indicated anatomical landmarks; multicavity active shape model; multiple heart cavity segmentation; principal component analysis; real-time visualization; statistical shape model; three-dimensional transesophageal echocardiography; tissue probability maps; tissue-blood classification; ultrasound artifacts; ventricle; weighted update scheme; whole heart ASM; whole-heart model; Cavity resonators; Computational modeling; Heart; Image segmentation; Shape; Ultrasonic imaging; Valves;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2013.006228
Filename :
7119998
Link To Document :
بازگشت