DocumentCode
2726718
Title
Two-dimensional autocorrelation method for ultrasound-based strain estimation
Author
Shamdasani, Vijay ; Kim, Yongmin
Author_Institution
Dept. of Bioeng., Washington Univ., Seattle, WA, USA
Volume
1
fYear
2004
fDate
1-5 Sept. 2004
Firstpage
1380
Lastpage
1383
Abstract
Ultrasound strain imaging maps the tissue stiffness in the region of interest by estimating strain when the tissue is stressed. Prestress and poststress ultrasound echoes are processed to estimate the displacements, and the strain image is computed by a spatial derivative of the estimated displacement. Due to the nature of derivative operations, smaller errors in displacement estimation can cause large noise in the computed strain image. When tissue displacements are estimated using the phase of the autocorrelation between the prestress and poststress data (i.e., 1D autocorrelation method), it has been previously reported that local variations in ultrasonic center frequency due to speckle can introduce errors in the estimated displacement. We have developed a new method to compute strain based on two-dimensional autocorrelation. By estimating the local ultrasound frequency, we can improve the accuracy of displacement estimates and hence reduce the noise in strain images. We have analyzed the effect of local frequency changes on noise in strain images and the improvement in the strain signal-to-noise ratio with the 2D autocorrelation method. The simulation results are supported by experiments with homogenous gelatin phantoms and show that strain signal-to-noise ratio with 2D autocorrelation is consistently higher than that with 1D autocorrelation. The 2D autocorrelation can increase the strain signal-to-noise ratio by up to 200%, which leads us to believe that our estimation method can significantly improve the quality of strain images.
Keywords
biological tissues; biomechanics; biomedical measurement; biomedical ultrasonics; correlation methods; displacement measurement; gelatin; numerical analysis; phantoms; strain measurement; gelatin phantoms; signal-to-noise ratio; speckle; strain estimation; strain image computation; stress effects; tissue displacement estimation; tissue stiffness; two-dimensional autocorrelation; ultrasound echo processing; ultrasound frequency estimation; ultrasound strain imaging; ultrasound-based strain estimation; Autocorrelation; Capacitive sensors; Estimation error; Frequency estimation; Image analysis; Noise reduction; Phase estimation; Signal to noise ratio; Speckle; Ultrasonic imaging; Ultrasound; autocorrelation; phase-based; strain; strain signal-to-noise ratio;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
Conference_Location
San Francisco, CA
Print_ISBN
0-7803-8439-3
Type
conf
DOI
10.1109/IEMBS.2004.1403430
Filename
1403430
Link To Document