    In clinical practice, Myocardial Blush Grade (MBG) has been used to obtain information about microvascular condition in myocardial infarction by using coronary angiogram. Quantitative Blush Evaluator (QuBE) program was developed for the calculation of myocardial perfusion score. Calculation of QuBE values is often affected by patient motion and become inaccurate. In this paper, we proposed an algorithm to reduce undesired motion in coronary angiogram. This algorithm correct frame motion by shifting each single frame according to the best correlation with the first frame. The effectiveness of this stablizing method achieved by searching scale-invariant feature from each frame of coronary angiogram in order to find the best correlation between two frame. The results showed that MBG categorization based on modified QuBE program exactly match with the original QuBE program. In addition, results also showed that application of stabilization algorithm using SIFT method decreased the deviation by 15% therefore it increased the accuracy of QuBE value calculation. Finally, this new algorithm also decreased the execution time by 71% so the doctor could faster patient diagnosis. In conclusion the new algorithm could enhance the qualitiy of QuBE value calculations in MBG scoring for coronary angiogram.
  • Keywords
    blood vessels; cardiology; diagnostic radiography; patient diagnosis; QuBE value calculation; SIFT method; coronary angiogram stabilization; myocardial blush grade; myocardial infarction; myocardial perfusion score; patient diagnosis; patient motion; quantitative blush evaluator program; stabilization algorithm; Angiography; Arteries; Correlation; Feature extraction; Instruments; Myocardium; Noise; coronary angiography; myocardial blush grade; quantitative blush evaluator; scale-invariant feature transform; stabilization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), 2011 2nd International Conference on
  • Conference_Location
    Bandung
  • Print_ISBN
    978-1-4577-1167-1
  • Type

    conf

  • DOI
    10.1109/ICICI-BME.2011.6108605
  • Filename
    6108605