DocumentCode
2728531
Title
A 110 dB THD, 18 mW DAC using output sampling and feedback to reduce distortion
Author
Thomsen, A. ; Kasha, D. ; Lei Wang ; Wai Lee
Author_Institution
Crystal Semicond. Div., Cirrus Logic Inc., Austin, TX, USA
fYear
1999
fDate
17-17 Feb. 1999
Firstpage
150
Lastpage
151
Abstract
A digital-to-analog converter (DAC) with -110 dB total harmonic distortion (THD) is required to generate signals for linearity tests of data acquisition channels and sensors. Low power and a minimal number of external components are important to the application. A 256 kHz noise shaped bit stream is provided with a maximum signal frequency of 100 Hz. The out-of-band quantization noise has to be attenuated to less than -50 dB. A topology that minimized the number of critical circuit blocks in the DAC is preferable to minimize the design tasks and risks.
Keywords
circuit feedback; digital-analogue conversion; harmonic distortion; quantisation (signal); 100 kHz; 18 mW; 256 kHz; DAC; THD; critical circuit blocks; data acquisition channels; feedback; linearity tests; noise shaped bit stream; out-of-band quantization noise; output sampling; Circuit noise; Data acquisition; Digital-analog conversion; Linearity; Noise shaping; Output feedback; Sampling methods; Signal generators; Testing; Total harmonic distortion;
fLanguage
English
Publisher
ieee
Conference_Titel
Solid-State Circuits Conference, 1999. Digest of Technical Papers. ISSCC. 1999 IEEE International
Conference_Location
San Francisco, CA
ISSN
0193-6530
Print_ISBN
0-7803-5126-6
Type
conf
DOI
10.1109/ISSCC.1999.759169
Filename
759169
Link To Document