Performance evaluation of recombinant lead-acid battery valves
Author :
Camp, Sharon R.
Author_Institution :
Contel Lab., Norcross, GA, USA
fYear :
1990
fDate :
22-25 Oct. 1990
Firstpage :
464
Lastpage :
467
Abstract :
Since the pressure relief valve regulates the internal pressure and oxygen content, it directly affects the efficiency and ultimately the life of a valve-regulated lead-acid battery. Despite the importance of the valve, however, no tests have been developed that can be used to evaluate the long-term performance of the valve. Although the test that is described is not designed to determine life expectancy, the results can be used in a comparative manner to determine which valve design is more likely to continue to perform as it ages. The Sonnenschein-type valve performed best after the simulated aging test, while the Bunsen-type valve performed the worst.<>
Keywords :
lead; secondary cells; Bunsen-type valve; Pb acid battery; Sonnenschein-type valve; efficiency; internal pressure; oxygen content; pressure relief valve; simulated aging test; valve regulated battery; Aging; Battery charge measurement; Communication industry; Laboratories; Life testing; Performance evaluation; Plastics; Resists; Safety; Valves;