• DocumentCode
    2730087
  • Title

    Localization of Electrical Shorts in Dies and Packages using Magnetic Microscopy and Lock-in-IR Thermography

  • Author

    Hechtl, M. ; Steckert, G. ; Keller, C.

  • Author_Institution
    Infineon Technol., Munich
  • fYear
    2006
  • fDate
    3-7 July 2006
  • Firstpage
    252
  • Lastpage
    255
  • Abstract
    Scanning SQUID microscopy (SSM) is used to visualize current paths on package and die level. In case studies it is shown, how the integration of SSM into the failure analysis flow and its combination with lock-in-IR thermography (LIT) makes it faster and allows more reliable interpretation of results
  • Keywords
    SQUIDs; infrared imaging; magnetic force microscopy; system-in-package; electrical shorts; lock-in-IR thermography; magnetic microscopy; scanning SQUID microscopy; Failure analysis; Metallization; Micromagnetics; Microscopy; SQUIDs; Semiconductor device packaging; Semiconductor devices; Signal processing; Stimulated emission; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits, 2006. 13th International Symposium on the
  • Conference_Location
    Singapore
  • Print_ISBN
    1-4244-0205-0
  • Electronic_ISBN
    1-4244-0206-9
  • Type

    conf

  • DOI
    10.1109/IPFA.2006.251041
  • Filename