• DocumentCode
    2733931
  • Title

    Finite element modelling of a 3 dimensional dielectrophoretic flow separator device for optimal bioprocessing conditions

  • Author

    Fatoyinbo, H.O. ; Hughes, M.P.

  • Author_Institution
    Centre for Biomed. Eng., Surrey Univ., Guildford, UK
  • Volume
    1
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    2587
  • Lastpage
    2590
  • Abstract
    Planar 2-dimensional dielectrophoresis electrode geometries are limited in only being capable of handling fluid volumes ranging from picolitres to hundreds of microliters per hour. A 3-dimensional electrode system has been developed capable of handling significantly larger volumes of fluid. Using finite element modeling the electric field distribution within various bore sizes was realized. From these simulations it is possible to optimize bioprocessing factors influencing the performance of a dielectrophoretic separator. Process calculations have shown that flow-rates of 25ml hr-1 or more can be attained for the separation of heterogeneous populations of bio-particles based on their dielectric properties.
  • Keywords
    biological techniques; cellular biophysics; electrophoresis; finite element analysis; flow separation; 3 dimensional dielectrophoretic flow separator device; bio-particles; dielectric property; electric field distribution; finite element modelling; optimal bioprocessing condition; Biomedical electrodes; Boring; Cells (biology); Dielectrics; Dielectrophoresis; Finite element methods; Geometry; Insulation; Particle separators; Throughput; 3-D modeling; Dielectrophoresis; bioprocess;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1403744
  • Filename
    1403744