DocumentCode
2734228
Title
Proper application & maintenance of molded case breakers to assure safe and reliable operation
Author
Higginson, Mark ; Durocher, David B.
Author_Institution
North Pacific Paper Corp., Longview, WA, USA
fYear
2009
fDate
21-26 June 2009
Firstpage
90
Lastpage
101
Abstract
This paper will discuss the importance of reliable and repeatable performance of molded case circuit breakers in today´s power distribution systems. The paper will review existing standards for maintenance of molded case breakers including procedures outlined in NEMA AB4 and IEEE1458. Common misconceptions and system application issues regarding these devices will be discussed. Several examples of on-line infrared scans of circuit breakers over the course of a five year period will be presented and reviewed. Experiences at an integrated paper mill located in Longview, Washington USA explains documented cases where infrared thermography has been used as a predictive maintenance tool in determining potential problems with breakers while in service. Follow-up analysis by the circuit breaker manufacturer has generally validated mill maintenance decisions to remove a breaker from service and replace it, based on infrared scan results. Periodic infrared scanning used as a tool in identifying potential problems with sealed molded case circuit breakers will be discussed. This and other breaker off-line testing methods used at this site will be reviewed. Finally, overall reliability improvement and impact on the results of the existing mill-wide safety compliance programs will be summarized.
Keywords
circuit breakers; electrical safety; maintenance engineering; paper mills; power distribution reliability; IEEE1458; NEMA AB4; circuit breakers; infrared thermography; integrated paper mill; molded case breaker maintenance; operation reliability; operation safety; periodic infrared scanning; power distribution systems; predictive maintenance tool; Circuit analysis; Circuit breakers; Circuit testing; Manufacturing; Milling machines; Paper mills; Power distribution; Power system reliability; Predictive maintenance; Safety; Electrical Safety Program; Infrared Thermography; Molded Case Circuit Breakers; NFPA70E Standard; Predictive Maintenance; Risk Management;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulp and Paper Industry Technical Conference, 2009. PPIC '09. Conference Record of 2009 Annual
Conference_Location
Birmingham, AL
ISSN
0190-2172
Print_ISBN
978-1-4244-3464-0
Electronic_ISBN
0190-2172
Type
conf
DOI
10.1109/PAPCON.2009.5185428
Filename
5185428