• DocumentCode
    2734398
  • Title

    Test device for radiated immunity tests

  • Author

    Heinrich, Ralf ; Streitwolf, Holger ; Dallwitz, Lothar ; Karsten, Uwe

  • Author_Institution
    TESEQ GmbH, Berlin
  • fYear
    2009
  • fDate
    12-16 Jan. 2009
  • Firstpage
    429
  • Lastpage
    432
  • Abstract
    A test device for radiated immunity tests has been developed. It allows obtaining a frequency dependent measurement value up to 3.4 GHz instead of a common pass/fail result. The characteristics of this test device have been investigated theoretically by numerical simulations and experimentally in GTEM cells.
  • Keywords
    TEM cells; electromagnetic coupling; immunity testing; GTEM cells; electromagnetic coupling structures; frequency-dependent measurement; radiated immunity tests; Electromagnetic coupling; Electromagnetic fields; Electromagnetic radiation; Electronic equipment testing; Frequency; Immunity testing; Optical fiber cables; Optical fiber devices; Optical fiber testing; Test facilities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2009 20th International Zurich Symposium on
  • Conference_Location
    Zurich
  • Print_ISBN
    978-3-9523286-4-4
  • Type

    conf

  • DOI
    10.1109/EMCZUR.2009.4783482
  • Filename