Abstract
Qualification testing of photovoltaic modules is a set of well-defined accelerated stress tests with strict pass/fail criteria based on functionality / performance, safety / insulation and visual requirements. This paper, third in series from the Photovoltaic Testing Laboratory of ASU / TUV Rheinland PTL, compares the overall failure rates obtained in three consecutive periods: 1997-2005, 2005-2007 and 2007-2009. This paper also presents a distribution of failures, for the 2007-2009 period, among the four pass criteria defined in the standard: Visual failure (for example, extensive delamination), dry insulation failure (safety issue), wet resistance failure (safety issue) and performance failure (power drop).
Keywords
failure analysis; life testing; solar cells; ASU; TUV Rheinland PTL; dry insulation failure; failure analysis; failures distribution; photovoltaic modules qualification testing; photovoltaic testing laboratory; strict pass-fail criteria; visual failure; well defined accelerated stress test; wet resistance failure; Photovoltaic systems; Qualifications; Resistance; Silicon; Stress; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Specialists Conference (PVSC), 2010 35th IEEE
Conference_Location
Honolulu, HI
ISSN
0160-8371
Print_ISBN
978-1-4244-5890-5
Type
conf
DOI
10.1109/PVSC.2010.5614459
Filename
5614459
Link To Document