• DocumentCode
    273752
  • Title

    HDL CW instrumentation system

  • Author

    Brackett, J. ; Rosenberg, Yuri ; McDonald, Diane

  • Author_Institution
    Harry Diamond Lab., Adelphi, MD, USA
  • fYear
    1989
  • fDate
    23-25 May 1989
  • Firstpage
    406
  • Lastpage
    409
  • Abstract
    The Harry Diamond Laboratories continuous wave instrumentation system (HDL/CWIS) was developed for studying electromagnetic pulse effects on a variety of equipment. The system consists of the electromagnetic field generating and data collecting/processing equipment. The data acquisition system and the physical and electromagnetic properties of the system are discussed. Field-mapping data and responses of simple antenna structures, which were measured as part of the system calibration testing, are presented. The quality of the radiated field (in terms of planarity, uniformity, and repeatability) are discussed quantitatively
  • Keywords
    automatic test equipment; calibration; data acquisition; electromagnetic pulse; field strength measurement; EM field data collecting equipment; EM field generating equipment; Harry Diamond Laboratories; antenna structures; continuous wave instrumentation system; data acquisition system; electromagnetic properties; electromagnetic pulse effects; radiated field; system calibration testing; Antenna measurements; Calibration; Data acquisition; EMP radiation effects; Electromagnetic fields; Electromagnetic measurements; Electromagnetic radiation; Hardware design languages; Instruments; Laboratories;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1989., IEEE 1989 National Symposium on
  • Conference_Location
    Denver, CO
  • Type

    conf

  • DOI
    10.1109/NSEMC.1989.37219
  • Filename
    37219