• DocumentCode
    2739301
  • Title

    Power factor correction in AC/DC converters: design and measuring problems

  • Author

    Papanikolaou, N.P. ; Polyzos, N.P. ; Tatakis, E.C.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Patras Univ., Greece
  • Volume
    1
  • fYear
    1998
  • fDate
    14-18 Oct 1998
  • Firstpage
    222
  • Abstract
    This paper presents the design and the real characteristics of a power factor correction (PFC) boost converter, operating at a power level of 1000 W and at a variable switching frequency (between 7 kHz and 100 kHz). The harmonic content of the input current of a PFC boost converter is monitorized and compared with the harmonic content of the input current of the traditional AC/DC conversion topology. Another issue that is discussed in this paper is the accuracy of different measuring instruments in function to the harmonic content of the measuring signal and the interference in the operational characteristics of this converter due to the presence of these instruments. Experimental results for the case of a traditional AC/DC converter as well as for the case of a PFC converter are exhibited
  • Keywords
    AC-DC power convertors; power conversion harmonics; power factor correction; switching circuits; 1000 W; 7 to 100 kHz; AC/DC converters; boost converter; input current harmonic content; interference; measuring instruments accuracy; power factor correction; variable switching frequency; Analog-digital conversion; DC-DC power converters; Instruments; Interference; Monitoring; Power factor correction; Power measurement; Switching converters; Switching frequency; Topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Harmonics and Quality of Power Proceedings, 1998. Proceedings. 8th International Conference On
  • Conference_Location
    Athens
  • Print_ISBN
    0-7803-5105-3
  • Type

    conf

  • DOI
    10.1109/ICHQP.1998.759890
  • Filename
    759890