• DocumentCode
    273993
  • Title

    Computer control and data processing a four regenerator heat exchanger

  • Author

    Alipoor, J. ; Harness, J.B.

  • Author_Institution
    Bradford Univ., UK
  • fYear
    1989
  • fDate
    18-20 Sep 1989
  • Firstpage
    273
  • Lastpage
    277
  • Abstract
    Investigates the transient performance of thermal regenerators using a four bed computer controlled system. The response of the regenerator has been investigated for step changes in various operating parameters, in particular gas flow rates, inlet temperature and period times; these experimental results are compared with the theoretical values
  • Keywords
    chemical engineering computing; computerised control; heat exchangers; microcomputer applications; four bed computer controlled system; gas flow rates; inlet temperature; multifunction interface unit; operating parameters; period times; regenerator heat exchanger; step changes; thermal regenerators; transient performance;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Software Engineering for Real Time Systems, 1989., Second International Conference on
  • Conference_Location
    Cirencester
  • Type

    conf

  • Filename
    51766