DocumentCode :
2740203
Title :
H emodynamic Interventions and the Pressure-Diameter Loop of the Left Ventricle and the Proximal Aorta in the Conscious Dog
Author :
Kerkhof, Peter L.M. ; Li, John K-J.
Author_Institution :
Dept. Medical Physics & Technology, Vrije Univ. Medical Center, P.O. Box 7057, 1007 MB Amsterdam, The Netherlands
Volume :
2
fYear :
2004
fDate :
1-5 Sept. 2004
Firstpage :
3636
Lastpage :
3638
Abstract :
The dynamics of the left ventricle (LV) have been extensively investigated. However, most studies refer to steady state conditions. We addressed the beat-to-beat variations resulting from hemodynamic interventions analyzed in the chronically instrumented dog. This approach permits serial studies in the same subject under physiological conditions. In particular we investigated the end-systolic pressure-dimension relationship and characteristics of the proximal aorta. The findings obtained during basal conditions, exercise and pharmacologic intervention indicate that several universal regulatory mechanisms are involved, besides various phenomena that exhibit a substantial degree of variability.
Keywords :
Cardiac ventricle; elastance; regulation of heart function; Animals; Biomedical measurements; Heart; Hemodynamics; Humans; Instruments; Power system modeling; Pressure measurement; Steady-state; Volume measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
Print_ISBN :
0-7803-8439-3
Type :
conf
DOI :
10.1109/IEMBS.2004.1404022
Filename :
1404022
Link To Document :
بازگشت