DocumentCode :
2742175
Title :
THz Spectroscopic Performance Comparison between Micro-Strip-Line Based Sensing Methods and Attenuated Total Reflection
Author :
Onuma, M. ; Ohkubo, T. ; Kitagawa, J. ; Kadoya, Y.
Author_Institution :
Hiroshima Univ., Hiroshima
fYear :
2006
fDate :
18-22 Sept. 2006
Firstpage :
466
Lastpage :
466
Abstract :
We have developed compact micro-strip-line-based sensor chips which are appropriate for sensing polar liquids. In order to evaluate the spectroscopic performance of sensor chips, we have compared the absorption coefficients of albumin/water system obtained by the sensor chip with those by the attenuated total reflection method.
Keywords :
absorption coefficients; attenuated total reflection; microsensors; microstrip components; submillimetre wave spectra; submillimetre wave spectroscopy; THz spectroscopic performance; absorption coefficients; albumin-water system; attenuated total reflection; microstrip-line based sensing methods; microstrip-line-based sensor chips; polar liquids sensing; Absorption; Frequency dependence; Frequency measurement; Liquids; Optical pulse generation; Optical reflection; Semiconductor device measurement; Sensor systems; Spectroscopy; Submillimeter wave technology;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Infrared Millimeter Waves and 14th International Conference on Teraherz Electronics, 2006. IRMMW-THz 2006. Joint 31st International Conference on
Conference_Location :
Shanghai
Print_ISBN :
1-4244-0400-2
Electronic_ISBN :
1-4244-0400-2
Type :
conf
DOI :
10.1109/ICIMW.2006.368674
Filename :
4222408
Link To Document :
بازگشت