DocumentCode :
274230
Title :
Calculation of temperature rises due to conductor losses in a radially-cooled turbogenerator rotor
Author :
Stephenson, P.L.
Author_Institution :
CEGB, London, UK
fYear :
1989
fDate :
13-15 Sep 1989
Firstpage :
150
Lastpage :
153
Abstract :
The rotor windings of large generators are usually cooled by hydrogen flowing through ducts within the winding. A detailed computer model, ROTH, has been developed to predict asymmetric temperature distributions. The original version was limited to rotors with axial cooling, but now it has been extended to handle radially-cooled rotors. The approximate method for estimating thermal bend has also been greatly improved. The author describes these enhancements, and validates them by comparing them with a simplified analytical solution, with an independently developed computer program and with limited experimental data
Keywords :
cooling; electric machine analysis computing; losses; rotors; synchronous generators; turbogenerators; ROTH; asymmetric temperature distributions; computer model; conductor losses; radially-cooled turbogenerator rotor; thermal bend;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Machines and Drives, 1989. Fourth International Conference on (Conf. Publ. No. ??)
Conference_Location :
London
Type :
conf
Filename :
55381
Link To Document :
بازگشت