DocumentCode :
2743714
Title :
Double step attenuation measurement technique for high attenuation of variable attenuators
Author :
Widarta, Anton
Author_Institution :
Nat. Metrol. Inst. of Japan, AIST, Tsukuba, Japan
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
30
Lastpage :
31
Abstract :
An accurate solution of a double step attenuation measurement technique with an internal gauge block for variable attenuators is presented. The solution is obtained by solving the signal flow graph of the circuit model with a small reflection coefficient (<;0.1) on each I/O port. Experimental results both of low and high attenuation values show good agreement with measurements of the conventional techniques.
Keywords :
attenuation measurement; attenuators; gauges; signal flow graphs; I-O port; circuit model; double step attenuation measurement technique; internal gauge block; signal flow graph solution; small reflection coefficient; variable attenuator; Attenuation; Attenuation measurement; Attenuators; Flow graphs; Integrated circuit modeling; Loss measurement; Reflection; Attenuation; attenuator; measurement techniques; mismatch;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6250643
Filename :
6250643
Link To Document :
بازگشت