• DocumentCode
    2743754
  • Title

    Investigation of systematic errors of an AC Josephson Voltage Standard

  • Author

    Filipski, Piotr S.

  • Author_Institution
    Nat. Res. Council Canada - INMS, Ottawa, ON, Canada
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    36
  • Lastpage
    37
  • Abstract
    This paper presents results of experiments quantifying two systematic errors associated with the calibrations by use of an AC Josephson Voltage Standard: the change in the voltage leads error with the change in the level of probe immersion in the liquid helium, and the effect of the internal inductance of a Josephson array. The measurements were performed at frequencies 100 kHz and above, however, they can be used in evaluating an error budget at lower frequencies.
  • Keywords
    Josephson effect; calibration; inductance; liquid helium; measurement errors; measurement standards; superconducting arrays; voltage measurement; AC Josephson voltage standard; Josephson array; calibration; frequency 100 kHz; inductance effect; liquid helium; probe immersion; systematic error; voltage lead error; Arrays; Helium; Inductance; Liquids; Probes; Standards; Voltage measurement; Digital-analog conversion; Josephson arrays; measurement uncertainty; quantization; signal synthesis; standards; voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250646
  • Filename
    6250646