DocumentCode
2744099
Title
Battery powered BION FES network
Author
Schulman, J.H. ; Mobley, J.P. ; Wolfe, J. ; Regev, E. ; Perron, C.Y. ; Ananth, R. ; Matei, E. ; Glukhovsky, A. ; Davis, R.
Author_Institution
Alfred Mann Found., Santa Clarita, CA, USA
Volume
2
fYear
2004
fDate
1-5 Sept. 2004
Firstpage
4283
Lastpage
4286
Abstract
The Alfred Mann Foundation is completing development of a coordinated network of BION® microstimulator/sensor (hereinafter implant) that has broad stimulating, sensing and communication capabilities. The network consists of a master control unit (MCU) in communication with a group of BION implants. Each implant is powered by a custom lithium-ion rechargeable 10 mW-hr battery. The charging, discharging, safety, stimulating, sensing, and communication circuits are designed to be highly efficient to minimize energy use and maximize battery life and time between charges. The stimulator can be programmed to deliver pulses in any value in the following range: 5 μA to 20 mA in 3.3% constant current steps, 7 μs to 2000 μs in 7 μs pulse width steps, and 1 to 4000 Hz in frequency. The preamp voltage sensor covers the range 10 μV to 1.0 V with bandpass filtering and several forms of data analysis. The implant also contains sensors that can read out pressure, temperature, DC magnetic field, and distance (via a low frequency magnetic field) up to 20 cm between any two BION implants. The MCU contains a microprocessor, user interface, two-way communication system, and a rechargeable battery. The MCU can command and interrogate in excess of 800 BlON implants every 10 ms, i.e., 100 times a second.
Keywords
electric sensing devices; magnetic sensors; microsensors; neuromuscular stimulation; pressure sensors; prosthetics; secondary cells; temperature sensors; 1 to 4000 Hz; 10 muV to 1 V; 5 to 20 mA; 7 to 2000 mus; BION implants; BION microstimulator/sensor; DC magnetic field sensor; bandpass filtering; battery powered BION FES network; lithium-ion rechargeable battery; master control unit; microprocessor; preamp voltage sensor; pressure sensor; temperature sensor; two-way communication system; user interface; Batteries; Biosensors; Circuits; Communication system control; Frequency; Implants; Magnetic sensors; Safety; Space vector pulse width modulation; Temperature sensors; BION; BPB; FES; FNS; Microstimulator; PM&R; TES; implantable; injectable; micropower; microsensor;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
Conference_Location
San Francisco, CA
Print_ISBN
0-7803-8439-3
Type
conf
DOI
10.1109/IEMBS.2004.1404193
Filename
1404193
Link To Document