Title :
Scattering parameter measurement comparison between NMC and INRIM on Vector Network Analyzer using WR15 and WR10 connectors
Author :
Shan, Yueyan ; Oberto, Luca ; Meng, Yu Song ; Neo, H. ; Brunetti, L. ; Sellone, Marco
Author_Institution :
Nat. Metrol. Centre (NMC), A*STAR (Agency for Sci., Technol. & Res.), Singapore, Singapore
Abstract :
This paper describes a bilateral comparison between two national metrology institutes, NMC, A*STAR from Singapore and INRIM from Italy, concerning scattering parameter measurements with WR15 (50 to 75 GHz) and WR10 (75 to 110 GHz) waveguides.
Keywords :
S-parameters; millimetre wave measurement; network analysers; waveguide couplers; A*STAR; INRIM; NMC; National Metrology Institute; WR10 connector; WR15 connector; frequency 50 GHz to 110 GHz; scattering parameter measurement; vector network analyzer; Calibration; Frequency measurement; Millimeter wave measurements; Reflection; Scattering parameters; Temperature measurement; Uncertainty; Bilateral comparison; measurement uncertainty; scattering parameters; waveguide;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
Print_ISBN :
978-1-4673-0439-9
DOI :
10.1109/CPEM.2012.6250678