Title :
Development of S-parameter standard for coaxial 3.5 mm connectors in the frequency range from 10 MHz to 100 MHz
Author :
Kishikawa, R. ; Shida, M. ; Horibe, M.
Author_Institution :
Nat. Metrol. Inst. of Japan (NMIJ), Tsukuba, Japan
Abstract :
This paper describes NMIJ´s activity of developing the S-parameter standard for 3.5 mm coaxial lines at radio frequency (i.e. from 10 MHz to 100 MHz). The long air line (i.e. 300 mm) is used as the primary standard in NMIJ. The S-parameters of the air line are evaluated by measuring the dimensions and insertion loss. The uncertainties of the S-parameters, estimated by Monte Carlo simulation, are sufficient small to practical use.
Keywords :
Monte Carlo methods; S-parameters; coaxial cables; Monte Carlo simulation; NMIJ activity; S-parameter standard; coaxial connectors; frequency 10 MHz to 100 MHz; insertion loss; size 3.5 mm; Conductors; Connectors; Length measurement; Loss measurement; Scattering parameters; Standards; Transmission line measurements; measurement; measurement standards; measurement uncertainty; metrological traceability; scattering parameters; transmission lines;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
Print_ISBN :
978-1-4673-0439-9
DOI :
10.1109/CPEM.2012.6250680