DocumentCode :
2744832
Title :
DC motor cooling considerations
Author :
Konstanty, Walter J.
Author_Institution :
Gen. Electr. Co., Erie, PA, USA
fYear :
2011
fDate :
19-23 June 2011
Firstpage :
159
Lastpage :
162
Abstract :
DC motors have been the workhorse of variable speed drives in the paper industry for many years. DC motors in paper mills are usually separately ventilated from a large common air supply. The quantity and quality of the cooling air can have a major impact on the DC motors´ performance, operation, maintenance and life between overhauls. Information presented here describes cooling air considerations, corrosive air and its effect on motor performance and life, and ways to assess and reduce this issue.
Keywords :
DC motors; cooling; variable speed drives; DC motor cooling; air supply; corrosive air; paper mill; variable speed drive; workhorse; AC motors; Brushes; Commutation; Contamination; Cooling; DC motors; Paper mills; Direct Current Motors; air sampling; cooling air; corrosion; corrosion coupons; separate ventilation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulp and Paper Industry Technical Conference (PPIC), Conference Record of 2011 Annual IEEE
Conference_Location :
Nashville, TN
ISSN :
0190-2172
Print_ISBN :
978-1-61284-272-1
Type :
conf
DOI :
10.1109/PPIC.2011.5983234