Abstract :
The results of a bilateral comparison on active/reactive power meter calibrations between the National Institute of Standards and Technology (NIST) and the National Research Council (NRC) will be presented. The comparison was implemented using a transfer standard consisting of a highly stable commercial sampling-type power/energy meter. The measurements were made at 120 V, 5A, 50 Hz and 60 Hz, at power factors of 1.0, 0.5 lead and lag, and 0.0 lead and lag.
Keywords :
calibration; power meters; reactive power; NIST quantum-based power standard; NRC current-comparator-based power standard; National Research Council; active-reactive power meter calibrations; bilateral comparison; current 5 A; frequency 50 Hz; frequency 60 Hz; high stable commercial sampling-type power-energy meter; voltage 120 V; Bridge circuits; Current measurement; Laboratories; NIST; Reactive power; Uncertainty; Current-comparator; power bridge; power standard; quantum; uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6250872
Filename :
6250872
Link To Document :
بازگشت