• DocumentCode
    2747952
  • Title

    Determination of phase angle errors of current shunts for wideband power measurement

  • Author

    Rydler, Karl-Erik ; Bergsten, Tobias ; Tarasso, Valter

  • Author_Institution
    SP Tech. Res. Inst. of Sweden, Borås, Sweden
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    284
  • Lastpage
    285
  • Abstract
    A new phase comparator for current shunts with frequency range to 1 MHz has been developed and a new method to determine the absolute phase angle error of current shunts is described. Preliminary expanded uncertainty of the absolute phase angle error for a reference shunt with resistance 1,5 Ω is ±200 μrad at 1 MHz. Based on the reference shunt the phase comparator is used to determine the phase angle errors of a shunt set. At 5 A, 100 kHz the new determination agrees within the expanded uncertainty ±100 μrad with our earlier realization.
  • Keywords
    phase comparators; power measurement; current 5 A; current shunts; expanded uncertainty; frequency 1 MHz; frequency 100 kHz; phase angle error determination; phase comparator; preliminary expanded uncertainty; resistance 1 ohm; resistance 5 ohm; wideband power measurement; Current measurement; Frequency measurement; Inductance; Measurement uncertainty; Phase measurement; Uncertainty; Voltage measurement; Measurement standards; measurement techniques; phase measurement; power measurement; shunt (electrical);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250913
  • Filename
    6250913