DocumentCode
2748237
Title
Reproduction of four base magnetic units in the unified standard of VNIIM
Author
Shifrin, V.Ya. ; Khorev, V.N. ; Kalabin, V.N. ; Voronov, S.L.
Author_Institution
D.I. Mendeleyev Inst. for Metrol. (VNIIM), St. Petersburg, Russia
fYear
2012
fDate
1-6 July 2012
Firstpage
314
Lastpage
315
Abstract
The described measurement standard is developed on the basis of modern magnetic measuring techniques to substitute three standards operated earlier at VNIIM. In the unified measuring system the standard reproduces four base units of magnetic quantities, as well as the ratios of these units to the ampere: magnetic flux density (MFD) - T, magnetic flux (MF) -Wb, magnetic moment - Am2 and MFD gradient - T/m. It allows realizing modern calibration system for magnetic measuring and reproducing instruments.
Keywords
calibration; magnetic flux; magnetic variables measurement; measurement standards; VNIIM; base magnetic units; magnetic flux density; magnetic measuring; magnetic moment; measurement standard; modern calibration system; unified standard; Geophysical measurements; Magnetic flux density; Magnetic moments; Magnetic resonance; Standards; Uncertainty; Measurement; gradient; magnetic field; magnetic flux density; magnetic moment; magnetic resonance; measuring system; standard; uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location
Washington, DC
ISSN
0589-1485
Print_ISBN
978-1-4673-0439-9
Type
conf
DOI
10.1109/CPEM.2012.6250928
Filename
6250928
Link To Document