• DocumentCode
    2748676
  • Title

    Voltage injection type high ohm resistance bridge

  • Author

    Oe, T. ; Kinoshita, J. ; Kaneko, N.

  • Author_Institution
    Nat. Metrol. Inst. of Japan (NMIJ), Tsukuba, Japan
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    360
  • Lastpage
    361
  • Abstract
    We propose a modified Wheatstone bridge for the high-value resistance measurement from 1 MΩ to 1 TΩ. In this system, single voltage source and a resistance voltage divider are used instead of dual DC voltage sources. This bridge has the additional voltage source, which injects voltage to the neutral point of the bridge to achieve balance. This new voltage injection type Wheatstone bridge can calibrate a 1 TΩ resistor with an uncertainty of 23 μΩ/Ω.
  • Keywords
    electric resistance measurement; voltage dividers; bridge neutral point; dual DC voltage sources; high ohm resistance bridge; high-value resistance measurement; modified Wheatstone bridge; resistance 1 Mohm to 1 Tohm; resistance voltage divider; single voltage source; voltage injection; Bridge circuits; Calibration; Electrical resistance measurement; Resistance; Resistors; Uncertainty; Voltage measurement; DC Resistance standards; High-value resistance measurement; Modified Wheatstone bridge; Resistance voltage divider;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6250951
  • Filename
    6250951