DocumentCode :
2749247
Title :
Determination and correction of mass exchange errors in the NRC watt balance
Author :
Sanchez, C.A. ; Wood, B.M. ; Inglis, A.D. ; Robinson, I.A.
Author_Institution :
Nat. Res. Council, Ottawa, ON, Canada
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
428
Lastpage :
429
Abstract :
We have investigated mass exchange corrections in the NRC watt balance. Two effects arising from mass exchanges during the weighing phase produce significant systematic errors in measurements of the Planck constant (h). These effects were estimated and corresponding corrections were applied to measurements of h made at NRC between August and September of 2011 An effect due to tilting of the beam required an estimated correction of (0.238 ± 0.018) μW/W and an effect due to tilting of the flat, which supports the beam, required an estimated correction of (-0.636 ± 0.056) μW/W.
Keywords :
balances; mass measurement; NRC watt balance; Planck constant measurements; beam tilting; mass exchange error correction; weighing phase; Coils; Copper; Current measurement; Elasticity; Force; Measurement uncertainty; Sensitivity; Beam balance; Planck´s constant; electronic kilogram; fundamental constants; watt balance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6250986
Filename :
6250986
Link To Document :
بازگشت