DocumentCode :
2749724
Title :
Uncertainty estimations of an evaluation system for a high accuracy and wideband transconductance amplifier
Author :
Kon, Saytaro ; Yamada, Tatsuji
Author_Institution :
Nat. Metrol. Inst. of Japan, Nat. Inst. of Adv. Ind. Sci. & Technol., Tsukuba, Japan
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
482
Lastpage :
483
Abstract :
An evaluation system for high accuracy transconductance amplifiers has been developed. The system has a standard ac shunt and inductive voltage divider for precise evaluations. The measurement capabilities of the system are 4.1×10-6 (k = 2) for in-phase component, 9.1×10-6 (k = 2) for quadrature component at power frequencies, and 13×10-6 for inphase component, 45×10-6 (k = 2) for quadrature component at 3 kHz.
Keywords :
amplifiers; voltage dividers; ac shunt voltage divider; evaluation system uncertainty estimations; high accuracy transconductance amplifier; in-phase component; inductive voltage divider; power frequencies; quadrature component; wideband transconductance amplifier; Accuracy; Calibration; Current measurement; Standards; Transconductance; Uncertainty; Wideband; IVD; Transconductance amplifier; ac shunt; calibration; frequency characteristic;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6251013
Filename :