• DocumentCode
    2750295
  • Title

    Comparison of non-quantum methods for calibration of digital sources of very-low-frequency AC voltage

  • Author

    Kampik, Marian

  • Author_Institution
    Silesian Univ. of Technol., Gliwice, Poland
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    544
  • Lastpage
    545
  • Abstract
    The paper presents methods of calibration of digital sources of AC voltage with very low frequency (0.001 - 100 Hz) and of effective value from 1 V to 7 V. The work deals primarily with calibration methods of digital sources of the sinusoidal signal which is approximated with the staircase waveform. Calibration methods are divided into dynamic and static. Of the dynamic methods the thermal method and integrating sampling method is described. Of the static methods the step and the peak-to-peak method of calibration is presented. The potential applications, basic features and accuracy of all the methods are discussed. The paper also contains a comparison of results obtained by means of presented methods of calibration.
  • Keywords
    approximation theory; calibration; sampling methods; calibration peak-to-peak method; digital source calibration; frequency 0.001 Hz to 100 Hz; nonquantum methods; sampling method; staircase waveform; static methods; thermal method; very-low-frequency AC voltageVoltage; voltage 1 V to 7 V; Accuracy; Calibration; Decision support systems; Frequency measurement; Standards; Voltage measurement; Voltmeters; AC voltage standard; AC-DC transfer; digital signal synthesis; thermal converter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6251044
  • Filename
    6251044