• DocumentCode
    2750394
  • Title

    Calibration of non-conventional instrument transformers

  • Author

    Crotti, G. ; Giordano, D. ; Cherbaucich, C. ; Mazza, P.

  • Author_Institution
    Ist. Naz. di Ricerca Metrol., Torino, Italy
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    558
  • Lastpage
    559
  • Abstract
    The paper focuses on the calibration techniques of non-conventional voltage and current measurement transformers. Calibration circuits set up at INRIM are described, which makes use of digital acquisition and numerical analysis of the transducer output. Examples of calibration of non-conventional instruments to be used as on-site references are discussed, which include a system based on Rogowski coil for live-on-site check of measuring current transformers with rated voltages up to 380 kV.
  • Keywords
    calibration; electric current measurement; numerical analysis; transducers; transformers; voltage measurement; INRIM; Rogowski coil; calibration circuits; current measurement transformer live-on-site check; digital acquisition; nonconventional current measurement transformer calibration techniques; nonconventional instrument transformer calibration techniques; nonconventional voltage measurement transformer calibration techniques; numerical analysis; on-site references; transducer output; Calibration; Current measurement; Current transformers; Instrument transformers; Optical sensors; Uncertainty; Voltage measurement; Calibration; High voltage.; measurement standards; measurement uncertainty; non-conventional instrument transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6251051
  • Filename
    6251051