• DocumentCode
    2751219
  • Title

    Design and construction of tapered cells

  • Author

    Shay, W.T. ; Hong, W.P. ; Lao, R.R.

  • Author_Institution
    Center for Meas. Stand./Ind. Technol. Res. Inst., Taiwan
  • fYear
    2012
  • fDate
    1-6 July 2012
  • Firstpage
    646
  • Lastpage
    647
  • Abstract
    Tapered cells are used in E-field probes calibration [1]-[2]. Nevertheless, few studies on tapered cells are found. In this paper, the structure of taper cells is introduced and a theoretical model for characteristic impedance calculation is provided. Based on this model, we constructed a tapered cell. And the model is then verified by the measured characteristic impedances of the tapered cell.
  • Keywords
    electric impedance; electromagnetic compatibility; probes; test equipment; characteristic impedance calculation; tapered cell; Calibration; Capacitance; Impedance; Impedance measurement; Probes; TEM cells; Transmission line measurements; Anechoic chamber; TEM cell; calibration; characteristic impedance; measurement; tapered cell;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2012 Conference on
  • Conference_Location
    Washington, DC
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4673-0439-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2012.6251095
  • Filename
    6251095