DocumentCode
2751219
Title
Design and construction of tapered cells
Author
Shay, W.T. ; Hong, W.P. ; Lao, R.R.
Author_Institution
Center for Meas. Stand./Ind. Technol. Res. Inst., Taiwan
fYear
2012
fDate
1-6 July 2012
Firstpage
646
Lastpage
647
Abstract
Tapered cells are used in E-field probes calibration [1]-[2]. Nevertheless, few studies on tapered cells are found. In this paper, the structure of taper cells is introduced and a theoretical model for characteristic impedance calculation is provided. Based on this model, we constructed a tapered cell. And the model is then verified by the measured characteristic impedances of the tapered cell.
Keywords
electric impedance; electromagnetic compatibility; probes; test equipment; characteristic impedance calculation; tapered cell; Calibration; Capacitance; Impedance; Impedance measurement; Probes; TEM cells; Transmission line measurements; Anechoic chamber; TEM cell; calibration; characteristic impedance; measurement; tapered cell;