DocumentCode :
2751465
Title :
Calibration system for AC measurement standards using a pulse-driven Josephson voltage standard and an inductive voltage divider
Author :
Hagen, Thomas ; Budovsky, Ilya ; Benz, Samuel P. ; Burroughs, Charles J.
Author_Institution :
Nat. Meas. Inst., Lindfield, NSW, Australia
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
672
Lastpage :
673
Abstract :
A pulse-driven ac Josephson voltage standard (ACJVS) has been set up at the National Measurement Institute, Australia (NMIA) with the assistance from the National Institute of Standards and Technology (NIST). The ACJVS forms the basis of a high precision calibration setup for ac measurement standards at audio frequencies. The ACJVS can presently produce up to 100 mV. A precision inductive voltage divider increases the measurement range to 100 V at frequencies from 57 Hz to 1 kHz. Preliminary measurements conducted on a thermal transfer standard and a voltmeter show agreement with the conventional calibration within its uncertainties.
Keywords :
Josephson effect; calibration; transfer standards; voltage dividers; voltage measurement; AC measurement standard; National Institute of Standards and Technology; National Measurement Institute; calibration system; frequency 57 Hz to 1 kHz; inductive voltage divider; pulse driven Josephson voltage standard; thermal transfer standard; voltage 100 V; voltmeter; Amplifiers; Australia; Calibration; Measurement standards; NIST; Voltage measurement; Ac voltage standard; Josephson arrays; Josephson junction; ac voltage measurement; inductive voltage divider; pulse-driven Josephson voltage standards;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6251108
Filename :
6251108
Link To Document :
بازگشت