DocumentCode
2751530
Title
Normalized site attenuation measurement of a semi-anechoic chamber in multiple test zones
Author
Türer, I. ; Uysal, M. ; Akmehmet, M.C. ; Bagdat, A.D.
Author_Institution
OTOKAR A.S., Sakarya, Turkey
fYear
2012
fDate
17-21 Sept. 2012
Firstpage
1
Lastpage
6
Abstract
In this paper, normalized site attenuation measurement process and results in a semi-anechoic chamber, recently constructed at Otokar in Turkey for EMC measurement of military and commercial vehicles, are presented. Measurements are performed for both horizontal and vertical polarizations with two different antenna separations at multiple positions in the chamber. Finally, the results are compared to theoretical site attenuation values to validate the chamber quality. It is proven that, in all of the test zones located at diverse locations in the test chamber, the deviations from theoretical values are within the limits defined by the standards.
Keywords
anechoic chambers (electromagnetic); antennas; electromagnetic compatibility; EMC measurement; antenna separation; commercial vehicle; horizontal polarization; military vehicle; normalized site attenuation measurement; semianechoic chamber; vertical polarization; Antenna measurements; Electromagnetic compatibility; Frequency measurement; Receiving antennas; Transmitting antennas; Vehicles; EMC test; Semi-anechoic chamber; site attenuation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC EUROPE), 2012 International Symposium on
Conference_Location
Rome
ISSN
2325-0356
Print_ISBN
978-1-4673-0718-5
Type
conf
DOI
10.1109/EMCEurope.2012.6396827
Filename
6396827
Link To Document