DocumentCode
2755537
Title
Comparison of bilinear and PID control on a test furnace at British Steel
Author
Dunoyer, A. ; Burnham, K.J. ; McAlpine, T.S.
Author_Institution
Control Theory & Applications Centre, Coventry Univ., UK
fYear
1996
fDate
35137
Firstpage
42491
Lastpage
42495
Abstract
This paper details the findings of a comparative study when a single-input single-output bilinear self-tuning controller, which has been developed by the Control Theory and Applications Centre of Coventry University, is applied to a re-heat furnace at British Steel, Swinden Technology Centre, Moorgate, Rotherham. The performance of the bilinear self-tuner is compared to that of an industry standard PID controller which had been previously tuned manually to achieve optimum performance. Whilst the performances of the two schemes are not dissimilar the bilinear approach with its online tuning facilities offers potential advantages over existing commercially available automatic loop tuning devices It is recommended that the bilinear controller should be further developed and extensively evaluated under demonstrator and real-time plant trials on continuously operated furnaces
Keywords
steel industry; British Steel; PID control; SISO bilinear self-tuning controller; automatic loop tuning devices; continuously operated furnaces; online tuning facilities; re-heat furnace; test furnace;
fLanguage
English
Publisher
iet
Conference_Titel
Adaptive Controllers in Practice - Part Two (Digest No: 1996/060), IEE Colloquium on
Conference_Location
London
Type
conf
DOI
10.1049/ic:19960414
Filename
573276
Link To Document