• DocumentCode
    275582
  • Title

    Flow imaging using ultrasonic time-resolved transmission mode tomography

  • Author

    Gai, H. ; Li, Y.C. ; Plaskowski, A. ; Beck, M.S.

  • Author_Institution
    Univ. of Manchester Inst. of Sci. & Technol., UK
  • fYear
    1989
  • fDate
    18-20 Jul 1989
  • Firstpage
    237
  • Lastpage
    241
  • Abstract
    Describes an image reconstruction algorithm for ultrasound tomography using time-resolved transmitting mode ultrasound. It is applicable to many ultrasound imaging areas and is particularly suitable for process tomography like multiphase flow imaging. The special feature of this algorithm is that it tests at a specific time the pulse´s arrival instead of attenuation information. This algorithm is developed from a system point of view therefore the data collection is discussed in detail. The system using transmitting mode algorithm substantially reduces the data measurement time compared to the one using reflection mode algorithm. In contrast the former can handle the data measurement with ease. The images reconstructed by this algorithm are encouraging and are ready for further processing if needed
  • Keywords
    acoustic imaging; acoustic signal processing; flow measurement; picture processing; acoustic signal processing; data collection; image reconstruction; reflection mode algorithm; ultrasonic time-resolved transmission mode tomography; ultrasound imaging;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Image Processing and its Applications, 1989., Third International Conference on
  • Conference_Location
    Warwick
  • Type

    conf

  • Filename
    132127