DocumentCode :
2757229
Title :
An upward connecting leader at tests of large-scale lightning-rod models
Author :
Syssoev, V.S. ; Bulatov, M.U. ; Suharevsky, D.I. ; Andreev, M.G. ; Kostinsky, A. Ju ; Kuhno, A.V. ; Makalsky, L.M. ; Mareev, E.A.
Author_Institution :
All-Russian Electro-Tech. Inst., Moscow, Russia
fYear :
2011
fDate :
1-4 Nov. 2011
Firstpage :
906
Lastpage :
908
Abstract :
Estimations of connecting leader length for grounded objects of various geometries have been performed. The data of experimental studies of protection zones for large-scale lightning-rod models of different types are presented. In experiments the connecting leaders developing towards a spark discharge from a high-voltage electrode were observed. Experimental results on protection zones are compared to calculations under Russian standards of lightning protection.
Keywords :
earth electrodes; lightning protection; sparks; Russian lightning protection standards; connecting leader length estimation; grounded objects; high-voltage electrode; large-scale lightning-rod model protection zones; large-scale lightning-rod model testing; spark discharge; upward connecting leader; Atmospheric modeling; Joining processes; Lead; Lightning protection; Sparks; Trajectory;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Lightning (APL), 2011 7th Asia-Pacific International Conference on
Conference_Location :
Chengdu
Print_ISBN :
978-1-4577-1467-2
Type :
conf
DOI :
10.1109/APL.2011.6111043
Filename :
6111043
Link To Document :
بازگشت