• DocumentCode
    2758420
  • Title

    Partial discharge diagnostics of defective medium voltage three-phase PILC cables

  • Author

    Hunter, J.A. ; Hao, L. ; Lewin, P.L. ; Walton, C. ; Michel, M.

  • Author_Institution
    EEE Group, Univ. of Southampton, Southampton, UK
  • fYear
    2012
  • fDate
    10-13 June 2012
  • Firstpage
    371
  • Lastpage
    375
  • Abstract
    There are a number of medium voltage (MV) power distribution cable networks worldwide that are constructed predominantly of mass impregnated paper cables - London being one of these. Paper insulated lead covered (PILC) cables were extensively laid in the 50s and 60s before the introduction of cheaper polymeric alternatives that were sufficiently reliable. The current operational state of these networks has shown a gradual increase in failure rates of the previously reliable paper cables that are drawing to the end of their expected design life. Utilities are faced with the prospect of the impending failure of large sections of their prized asset and are keen to develop tools to better understand the health of their hardware. The analysis of partial discharge (PD) signals produced by the cables has been identified as a economically viable option to provide continuous condition monitoring of PILC cable circuits. Clearly, a comprehensive understanding of how PD activity relates to the various failure mechanisms exhibited by cable circuits in the field is required. In order to generate representative and repeatable PD signals from a number of PILC cable samples under rated conditions, an experiment was designed and commissioned. The scope of this paper is to introduce two cable degradation mechanisms that were applied to test cable and show the associated PD activity that was produced. A recently published technique for PD source discrimination was coupled with an understanding of the system and applied to the experiment data to isolate the signals specific to each degradation mechanism.
  • Keywords
    condition monitoring; impregnated insulation; lead; paper; partial discharges; power cable insulation; power distribution faults; power distribution lines; remaining life assessment; London; PD activity; PD signals; PD source discrimination; cable degradation mechanism; continuous condition monitoring; defective medium-voltage three-phase PILC cables; design life; failure rate; impregnated paper cables; medium voltage power distribution cable networks; paper insulated lead covered cable; partial discharge diagnostics; Degradation; Monitoring; Noise; Partial discharges; Power cable insulation; Power cables; Condition monitoring; Medium voltage plant; Paper insulated lead covered distribution cable; Partial discharge;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
  • Conference_Location
    San Juan, PR
  • ISSN
    1089-084X
  • Print_ISBN
    978-1-4673-0488-7
  • Electronic_ISBN
    1089-084X
  • Type

    conf

  • DOI
    10.1109/ELINSL.2012.6251492
  • Filename
    6251492