DocumentCode
2759178
Title
On-site transformer partial discharge diagnosis
Author
Gross, Detlev W. ; Soeller, Markus
Author_Institution
Power Diagnostix Syst. GmbH, Aachen, Germany
fYear
2012
fDate
10-13 June 2012
Firstpage
558
Lastpage
564
Abstract
In the lab, partial discharge diagnosis has widely replaced the traditional RIV measurements. Additionally, partial discharge acceptance levels are being reduced due to the increasing use of composite material and a growing awareness of partial discharge phenomenon and their consequences. Adequate filtering of the supply voltage for induced voltage testing and the use of sensitive acoustic measurement has greatly improved the detection and location of partial discharge activity in power transformers. An increasing population of service aged substation equipment having reached their projected service life demands on-site repair and, hence, on-site testing to factory standards. Using inverter based three-phase mobile test sets allows on-site application of tests previously limited to a mere test room environment. Besides the unmatched portability of inverter-based sources, especially the less critical generation of reactive power simplifies on-site testing, if compared with motor-generator sets. Additionally, the lack of high short circuit currents limits the damage in case of breakdown. However, adequately removing the switching noise spectrum becomes a demanding task in order to reach the required sensitivity of the partial discharge measurements.
Keywords
acoustic measurement; maintenance engineering; partial discharge measurement; power transformer testing; transformer substations; RIV measurements; acoustic measurement; composite material; factory standards; induced voltage testing; inverter-based three-phase mobile test sets; motor-generator sets; onsite repair; onsite testing; onsite transformer partial discharge diagnosis; partial discharge acceptance levels; partial discharge activity detection; partial discharge activity location; partial discharge measurement sensitivity; power transformers; reactive power; service aged substation equipment; service life; short circuit currents; supply voltage filtering; switching noise spectrum; Inverters; Mobile communication; Noise; Partial discharges; Power transformer insulation; Testing; acoustic location; diagnosis; inverter-based; on-site; partial discharge;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
Conference_Location
San Juan, PR
ISSN
1089-084X
Print_ISBN
978-1-4673-0488-7
Electronic_ISBN
1089-084X
Type
conf
DOI
10.1109/ELINSL.2012.6251532
Filename
6251532
Link To Document