DocumentCode :
2759441
Title :
A comparison of partial discharge detection with 50 Hz and 0,1 Hz at XLPE Cables
Author :
Sumereder, Christof
Author_Institution :
Inst. of High Voltage Eng. & Syst. Manage. - IHS, Graz Univ. of Technol., Graz, Austria
fYear :
2012
fDate :
10-13 June 2012
Firstpage :
619
Lastpage :
622
Abstract :
In this paper the results of different cable test techniques were compared. On the one hand the classical 50 Hz method for partial discharge detection and on the other hand the very low frequency method - VLF - at 0,1 Hz was examined. Additionally the oscillating wave method was applied onsite in an aged medium voltage grid with several joints of a local utility.
Keywords :
XLPE insulation; fault location; partial discharge measurement; power cable insulation; power cable testing; power grids; radiofrequency measurement; VLF method; XLPE Cables; aged medium voltage grid; cable fault location; cable test techniques; frequency 0.1 Hz; frequency 50 Hz; oscillating wave method; partial discharge detection; very low frequency method; Cable shielding; Joints; Partial discharge measurement; Partial discharges; Power cables; Reflection; Voltage measurement; VLF; cable fault location; diagnostic testing; dissipation factor; oscillating waves; partial discharges;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
Conference_Location :
San Juan, PR
ISSN :
1089-084X
Print_ISBN :
978-1-4673-0488-7
Electronic_ISBN :
1089-084X
Type :
conf
DOI :
10.1109/ELINSL.2012.6251545
Filename :
6251545
Link To Document :