• DocumentCode
    2759494
  • Title

    Quantifying the Advantages of Counter Flow Helium First Wall Cooling A Thermal-Hydraulic Comparison of ITER TBM First Wall Cooling Designs

  • Author

    Sviatoslavsky, G. ; Dagher, M. ; Calderoni, Pattrick ; Wong, C.P.C.

  • Author_Institution
    Wisconsin Univ., Madison, WI
  • fYear
    2005
  • fDate
    Sept. 2005
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Three dimensional computational fluid dynamic (CFD) calculations using the commercial software FLUENT, were performed to evaluate the thermal hydraulic performance of a counter flowing helium first wall (FW) cooling system compared to a more simple unidirectional flowing FW cooling system
  • Keywords
    Tokamak devices; computational fluid dynamics; fusion reactor blankets; fusion reactor design; ITER TBM first wall cooling design; commercial software FLUENT; counter flow helium first wall cooling; test blanket module; thermal hydraulic performance; three dimensional computational fluid dynamics; unidirectional flowing FW cooling system; Assembly; Computational fluid dynamics; Coolants; Cooling; Counting circuits; Helium; Performance evaluation; Software performance; Steel; Temperature; CFD; ITER; first wall; helium cooling; test blanket module; thermal-hydraulic analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering 2005, Twenty-First IEEE/NPS Symposium on
  • Conference_Location
    Knoxville, TN
  • Print_ISBN
    0-4244-0150-X
  • Electronic_ISBN
    0-4244-0150-X
  • Type

    conf

  • DOI
    10.1109/FUSION.2005.252901
  • Filename
    4018935