• DocumentCode
    2762731
  • Title

    Determination of Lead in Lipstick by Microwave Digestion and FAAS

  • Author

    Dong-mei, Wang ; Yu, Chen ; Zheng-jun, Gong ; Ying, Liu

  • Volume
    2
  • fYear
    2010
  • fDate
    6-7 March 2010
  • Firstpage
    297
  • Lastpage
    298
  • Abstract
    To establish a method for determination of lead in lipstick with microwave digestion and FAAS. Microwave digestion of samples with selected digestion conditions and FAAS were used to determine Pb in 10 lipstick samples. In the system of nitric acid (7.5 ml) and hydrogen peroxide (1.5ml), the time of microwave digestion was 10 minutes; a better result of digestion was obtained. The linear range and the detection limit of this method was 0.003 mg/l and 0.9994 respectively. The recovery rates of this method were 94.6%??102.5%. This method is satisfied for determination of lead in lipstick samples.
  • Keywords
    Chemical industry; Electromagnetic heating; Electromagnetic wave absorption; Electronics industry; FAA; Instruments; Lead; Metals industry; Microwave theory and techniques; Testing; FAAS; Lead; Microwave Digestion; lipstick;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Challenges in Environmental Science and Computer Engineering (CESCE), 2010 International Conference on
  • Conference_Location
    Wuhan, China
  • Print_ISBN
    978-0-7695-3972-0
  • Electronic_ISBN
    978-1-4244-5924-7
  • Type

    conf

  • DOI
    10.1109/CESCE.2010.137
  • Filename