DocumentCode
2762800
Title
The Design and Fabrication of a Full Field Quantitative Mammographic Phantom
Author
Hamza, Alnazier O M
Author_Institution
Biomed. Eng. Dept., Sudan Univ. of Sci. & Technol., Khartoum
fYear
2008
fDate
18-20 Dec. 2008
Firstpage
1
Lastpage
4
Abstract
Breast cancer is among the leading causes of death in women worldwide. Screen-film mammography (SFM) is still the standard method used to detect early breast cancer thus leading to early treatment. Digital mammography (DM) has recently been designated as the imaging technology with the greatest potential for improving the diagnosis of breast cancer. For successful mammography, high quality images must be achieved and maintained, and reproducible quantitative quality control (QC) testing is thus required. Assessing images of known reference phantoms is one accepted method of doing QC testing. Quantitative QC techniques are useful for the long-term follow-up of mammographic quality. Following a comprehensive critical evaluation of available mammography phantoms, it was concluded that a more suitable phantom for DM could be designed. A new relatively inexpensive Applied Physics Group (APG) phantom was designed to be fast and easy to use, to provide the user with quantitative and qualitative measures of high and low contrast resolution over the full field of view and to demonstrate any geometric distortions. It was designed to cover the entire image receptor so as to assess the heel effect, and to be suitable for both SFM and DM. The APG phantom was designed and fabricated with embedded test objects and software routines were developed to provide a complete toolkit for SFM and DM QC. The test objects were investigated before embedding them.
Keywords
biomedical equipment; cancer; diagnostic radiography; mammography; measurement standards; phantoms; APG phantom; Applied Physics Group; breast cancer; digital mammography; full field quantitative mammographic phantom; heel effect; mammography quality control; reference phantom mammographic image assessment; screen film mammography; Breast cancer; Cancer detection; Delta modulation; Distortion measurement; Fabrication; Imaging phantoms; Mammography; Physics; Quality control; Software testing; digital mammography; mammography; phantom; quality control;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Engineering Conference, 2008. CIBEC 2008. Cairo International
Conference_Location
Cairo
Print_ISBN
978-1-4244-2694-2
Electronic_ISBN
978-1-4244-2695-9
Type
conf
DOI
10.1109/CIBEC.2008.4786058
Filename
4786058
Link To Document