• DocumentCode
    276325
  • Title

    Design and tests of a 6 MW, 10000 RPM induction motor

  • Author

    Gilon, D.C.

  • fYear
    1991
  • fDate
    11-13 Sep 1991
  • Firstpage
    6
  • Lastpage
    10
  • Abstract
    The use of high speed electrical motors for direct driving of compressors may be very interesting in terms of installation or maintenance costs and reliability. During the 1980s; ACEC ENERGIE developed the concept of a high speed induction generator driven by two overhung impellers, using the expansion power of natural gas. The same concept of a central motor flanked by two overhung impellers has been used in an induction motor application, for natural gas pipeline compression stations. The authors describe this 6 MW, 10000 RPM application and also show how this high speed electrical motor design may comply with other industrial applications
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1991. Fifth International Conference on (Conf. Publ. No. 341)
  • Conference_Location
    London
  • Print_ISBN
    0-85296-520-6
  • Type

    conf

  • Filename
    153954